Industrial automation.

Automation and control solutions for industrial equipment and processes, using PLC, HMI, SCADA, controllers, remote I/O, VFDs and industrial communication systems.

Programmable control & SCADA

We engineer scalable PLC and SCADA architectures that automate complex process steps, enforce safety interlocks and provide intuitive operator control.

Panel PC sizes
7–21.5"
Enclosure rating
IP66
Tested twice
FAT + SAT
Engineer programming a PLC control panel from a laptop
Capabilities

Everything between the sensor and the motor.

Hardware, software and panels from one team, so there is no gap between who designed it and who makes it work.

PLC Systems
01

PLC Systems

Compact and modular PLCs with high-speed CPU logic and expansion I/O for temperature, analogue loops and encoder counting, delivered with programming and commissioning support.

Compact & modularSafety interlocksIEC 61131-3
HMI & Industrial Panel PCs
02

HMI & Industrial Panel PCs

Operator panels with the approvals your site requires, and IP65 marine-approved, fanless touch panel PCs from 7" to 21.5" for harsh washdown environments.

7" – 21.5"IP65 Marine panel
SCADA Systems
03

SCADA Systems

Centralised command suites that bring every station onto one screen: mimic graphics, alarm management, historical trending and reporting.

AlarmsTrendsReports
Remote I/O & Communications
04

Remote I/O & Communications

Distributed I/O racks and gateways communicating over PROFINET, Modbus TCP, EtherNet/IP and BACnet, so signals are wired once, close to the equipment.

PROFINETModbus TCPEtherNet/IPBACnet
VFDs & Motor Control
05

VFDs & Motor Control

Variable frequency drive cabinets for pumps, HVAC chillers, blowers and conveyors, plus soft starters, smart relay protection and MCC integration.

VFDSoft startersMCC
Control Panels
06

Control Panels

Custom NEMA / IP66 enclosures and field cabling assemblies: electrical CAD design, panel assembly, bench FAT testing and site SAT loop wiring.

NEMA / IP66FAT & SATCAD drawings
Power Quality & Energy
07

Power Quality & Energy

Panel-mount kWh meters, harmonic analysers and peak demand logging modules that show where energy goes and what it costs.

kWhHarmonicsPeak demand
Data Acquisition
08

Data Acquisition

Reliable collection, time-stamping and storage of process data, ready for reporting, analysis and connection to enterprise systems.

LoggingHistorianSQL
PROFINET Modbus TCP Modbus RTU EtherNet/IP BACnet OPC UA MQTT HART
Pumps and motors driven by VFDs, soft starters and energy meters
Motor control & energy management

Run slower. Spend less. Last longer.

Smart motor control assemblies lower operational energy consumption and prolong equipment life. A pump that follows demand instead of running flat out against a throttled valve pays for its drive quickly.

  • Variable Frequency Drives

    Speed control cabinets for pumps, HVAC chillers, blowers and conveyors.

  • Soft Starters & MCCs

    Reduced-voltage motor starters, smart relay protection and custom power control panels.

  • Power Quality Auditing

    Panel-mount kWh meters, harmonic analysers and peak demand logging modules.

FAQ

Questions we hear most.

Not answered here? Ask an engineer directly.

Ask on WhatsApp

What is the difference between a PLC, an HMI and SCADA?

A PLC is the industrial controller that reads sensors and operates equipment according to its program. An HMI is the local operator screen for a machine or panel. SCADA is the supervisory system that collects data from many PLCs and presents plant-wide graphics, alarms, trends and reports.

How does a variable frequency drive (VFD) save energy?

A VFD adjusts motor speed to match demand instead of running at full speed against a throttled valve or damper. On pumps and fans, a small reduction in speed gives a large reduction in power, and soft starting also reduces mechanical stress.

Can you integrate equipment from different manufacturers?

Yes. Procsol provides multi-vendor integration across leading brands including Siemens, ABB, Endress+Hauser and Schneider, using open protocols such as PROFINET, Modbus TCP, EtherNet/IP and BACnet.

What are FAT and SAT?

FAT is the factory acceptance test, where the control panel and software are tested on the bench before shipping. SAT is the site acceptance test, performed after installation with loop checks and calibration, before the system goes live.

Do you build custom control panels?

Yes. Procsol designs and builds custom NEMA / IP66 control panels, including electrical CAD drawings, panel assembly, bench FAT testing and site SAT loop wiring.